Electric Gates, Garage Door, Access Control, Smart Home & Security Forums

Full Version: CAME Frog and Daitem 902
You're currently viewing a stripped down version of our content. View the full version with proper formatting.
I'm installing a CAME Frog AE24 system with a Daitem 902 entry phone. No problem with power or connecting the "open" command wires. But I'd like to have the Daitem handsets show when the gates are open - and i don't want to fit a position switch.

So, I see that the Came controller (ZLJ24) will turn on a 24V bulb connected between pins 5 and 10 when the gates are open. So I could connect this to the coil of a 24V relay and use that to mimic a position switch

Anyone see a problem with this?

Is there a better way?

Thanks in advance
James
Seems like the best way to do it. I have used a door contact in the past but this seems like a better way. So I thank you for the idea for the future.

Thanks
Steve