marcuswilky

I have a problem!
I am using a CB24 controler and 2 LYN400-24 operators.
And I have checked all wiring several times.
My problem is that when I set up the limits the unit accepts them but then when I operate the gates from the closed position only gate 1 opens then when I close the gates, gate 1 closes and gate 2 opens at the same time.

I am puzzled, anybody got any ideas?
You have programmed 1 x gate Backwards or programmed the remote control into just cH 1 instead of CH2. You need to close both the gates manually then program the gates from the close possition.
Press learn limit , then use arrow button for gate 1 to send it open then arrow for gate 2 to send it open then press learn limit then use arrow to close gate 2 then arrow to close gate 1 then press learn limits and all should be fine.